Manufacturer Name | Polycab India Ltd. |
Cable type/Code | Solar DC Cable ‘H1Z2Z2-K’ as per BS EN 50618 |
Rated a.c. Voltage | 1.0/1.0 kV |
Nominal d.c. Voltage | 1.5 kV (Between Conductors as well as between Conductor & Earth) |
Specifications
Conductor | Â |
Material | Annealed Tinned Flexible copper conductor as per Class 5 of EN 60228 |
Conductor Size | 4 Sq.mm |
Max. D.C Cond. Resistance at 20 Deg. C. | 5.09 Ohm/Km |
 |  |
Insulation | Â |
Material | E beam XLPO Compound (Polyolefin Type) as per Annexure B Table B.1 of BS EN 50618 |
Nominal Thickness | 0.7 mm |
Minimum Thickness at point | 0.53 mm |
Core Identification | Black / Red |
Minimum Insulation Resistance at 20°C | 580 MΩ.km |
Minimum Insulation Resistance at 90°C | 0.58 MΩ.km |
Tensile Strength | 8 N/mm2 according to EN 60811 |
Elongation at Break | 125% according to EN 60811 |
 |  |
SHEATH | Â |
Material | E beam XLPO Compound (Polyolefin Type) as per Annexure B Table B.1 of BS EN 50618 |
Nominal Thickness | 0.8 mm |
Minimum Thickness at point | 0.58 mm |
Sheath Colour | Black with White Strip Black with Red Strip |
Tensile Strength | 8 N/mm2 according to EN 60811 |
Elongation at Break | 125% according to EN 60811 |
Overall Diameter ( Max.) | 6.6 mm |
Shape of Cable | Circular |
 |  |
Property of Cable | Â |
Current carrying capacity | Â |
Single cable free in air | 55 A |
Single cable on a surface | 52 A |
Two loaded cables touching, on a surface | 44 A |
Lower operating temperature | – 40°C |
Upper operating temperature | + 90°C |
Max. conductor temp. under normal operating conditions | 120°C (20000h) |
Max. conductor temp at the termination of short circuit | 250°C for 5seconds |
HV Test (A.C.) | 6.5 kV for 5 Mins. |
(D.C.) | 15 kV for 5 Mins. |
Surface Resistance Test | ⥠10 9 as per BS 50395 |
Standards to which the cables confirm | BS EN 50618, Flame retardant according to IEC 60332-1- |
 | 2,Halogen free according to EN 50627-2-2,Ozone resistant according EN 50396,Weather/UV resistant according to DIN 53387 |
Recommended minimum bending radius in mm | 8 – 10 times the overall diameter of the cable |
Max. Tensile strength when pulled with pulling eye | 20 Kg |
Printing @ one meter interval | YEAR POLYCAB 1.5 KV DC SOLAR CABLE âH1Z2Z2-Kâ |
 | 4 SQMM EBXL TUV Rheinland EN 50618:2014 |
YEAR POLYCAB 1.5 KV DC SOLAR CABLE âH1Z2Z2-Kâ | Â |
6 SQMM EBXL TUV Rheinland EN 50618:2014 | Â |